Siemens SINAMICS S Series - p3835[0...n] Friction characteristic, value F5; Friction F5; p3836[0...n] Friction characteristic, value M6; Friction M6; p3836[0...n] Friction characteristic, value F6; Friction F6; p3837[0...n] Friction characteristic, value M7; Friction M7

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-755
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 6th value pair of the friction characteristic.
Dependency: Refer to: p3825, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 7th value pair of the friction characteristic.
Dependency: Refer to: p3826, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 7th value pair of the friction characteristic.
Dependency: Refer to: p3826, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 8th value pair of the friction characteristic.
Dependency: Refer to: p3827, p3845
p3835[0...n] Friction characteristic, value F5 / Friction F5
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3836[0...n] Friction characteristic, value M6 / Friction M6
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p3836[0...n] Friction characteristic, value F6 / Friction F6
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3837[0...n] Friction characteristic, value M7 / Friction M7
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]