List of parameters
Parameters
1-755
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 6th value pair of the friction characteristic.
Dependency: Refer to: p3825, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 7th value pair of the friction characteristic.
Dependency: Refer to: p3826, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 7th value pair of the friction characteristic.
Dependency: Refer to: p3826, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 8th value pair of the friction characteristic.
Dependency: Refer to: p3827, p3845
p3835[0...n] Friction characteristic, value F5 / Friction F5
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3836[0...n] Friction characteristic, value M6 / Friction M6
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p3836[0...n] Friction characteristic, value F6 / Friction F6
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3837[0...n] Friction characteristic, value M7 / Friction M7
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]