Parameters
List of parameters
1-756
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 8th value pair of the friction characteristic.
Dependency: Refer to: p3827, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 9th value pair of the friction characteristic.
Dependency: Refer to: p3828, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the F coordinate of the 9th value pair of the friction characteristic.
Dependency: Refer to: p3828, p3845
Description: The friction characteristic is defined by 10 value pairs.
This parameter specifies the M coordinate of the 10th value pair of the friction characteristic.
Dependency: Refer to: p3829, p3845
p3837[0...n] Friction characteristic, value F7 / Friction F7
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3838[0...n] Friction characteristic, value M8 / Friction M8
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]
p3838[0...n] Friction characteristic, value F8 / Friction F8
SERVO (Lin) Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [N] 1000000.00 [N] 0.00 [N]
p3839[0...n] Friction characteristic, value M9 / Friction M9
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 7010
P-Group: Functions Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-1000000.00 [Nm] 1000000.00 [Nm] 0.00 [Nm]