List of parameters
Parameters
1-825
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the filtered speed setpoint N_SETPT in revolutions per minute for diagnostic purposes.
In contrast to p1155, this value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
Dependency: Refer to: r4154
Description: Is used to synchronize the timer of terminal module 17 (TM17) with the system time of the DP master.
To do this, the sign-of-life of the DP master is transferred in the form of a counter in bits 12 to 15.
At each cycle of the system of the DP master, bit 0 (SYN signal) is set for the duration of a DP master clock cycle.
Description: Is used to synchronize the timer of terminal module 15 (TM15) with the system time of the DP master.
To do this, the sign-of-life of the DP master is transferred in the form of a counter in bits 12 to 15.
At each cycle of the system of the DP master, bit 0 (SYN signal) is set for the duration of a DP master clock cycle.
Description: Used to control digital output 0 ... 15 of terminal module 17 (TM17).
r4155 TM41 diagnostics speed setpoint / TM41 Diag n_set
TM41 Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 9674
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r4201 TM17 system time for synchronization / TM17 t_system sync
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4201 TM15 system time for synchronization / TM15 t_system sync
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4204 TM17 control digital output 0 ... 15 / TM17 ctrl DO 0-15
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI/DO 0 (X520.2) On Off -
01 DI/DO 1 (X520.3) On Off -
02 DI/DO 2 (X520.5) On Off -
03 DI/DO 3 (X520.6) On Off -
04 DI/DO 4 (X520.8) On Off -
05 DI/DO 5 (X520.9) On Off -
06 DI/DO 6 (X521.2) On Off -
07 DI/DO 7 (X521.3) On Off -
08 DI/DO 8 (X521.8) On Off -