List of parameters
Parameters
1-843
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the edge status for digital input 0 ... 7 of terminal module 17 (TM17).
Assignment of the digital inputs to the bits:
DI 0: r4311.1 ... 0
DI 1: r4311.3 ... 2
DI 2: r4311.5 ... 4
DI 3: r4311.7 ... 6
DI 4: r4311.9 ... 8
DI 5: r4311.11 ... 10
DI 6: r4311.13 ... 12
DI 7: r4311.15 ... 14
Possible edge states:
Bit x, y = 0, 0 --> no edge detection
Bit x, y = 0, 1 --> 1st edge detected
Bit x, y = 1, 0 --> 2nd edge detected
Bit x, y = 1, 1 --> both edges detected
Note: DI: Digital input
Description: Displays the edge status for digital input 0 ... 7 of terminal module 15 (TM15).
Assignment of the digital inputs to the bits:
DI 0: r4311.1 ... 0
DI 1: r4311.3 ... 2
DI 2: r4311.5 ... 4
DI 3: r4311.7 ... 6
DI 4: r4311.9 ... 8
DI 5: r4311.11 ... 10
DI 6: r4311.13 ... 12
DI 7: r4311.15 ... 14
Possible edge states:
Bit x, y = 0, 0 --> no edge detection
Bit x, y = 0, 1 --> 1st edge detected
Bit x, y = 1, 0 --> 2nd edge detected
Bit x, y = 1, 1 --> both edges detected
Note: DI: Digital input
r4311 TM17 edge status digital input 0 ... 7 / TM17 EdgSt DI 0-7
TM17 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r4311 TM15 edge status digital input 0 ... 7 / TM15 EdgSt DI 0-7
TM15 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -