Description: Sets the bandwidth for the signal to be generated for the function generator.
Dependency: Only effective when p4820 = 4 (PRBS).
Refer to: p4830
Refer to: A02041
Description: Sets the amplitude for the signal to be generated for the function generator.
Dependency: Units are dependent on p4810.
If p4810 = 1, 2, 4: The amplitude is referred to p2002 (reference current).
If p4810 = 3, 5: The amplitude is referred to p2000 (reference speed).
Description: Sets the second amplitude for the signal to be generated for the function generator.
Dependency: Only effective for p4820 = 2 (staircase).
Units are dependent on p4810.
If p4810 = 1, 2, 4: The amplitude is referred to p2002 (reference current).
If p4810 = 3, 5: The amplitude is referred to p2000 (reference speed).
Description: Sets the offset (DC component) of the signal to be generated for the function generator.
Dependency: Units are dependent on p4810.
If p4810 = 1, 2, 4: The offset is referred to p2002 (reference current).
If p4810 = 3, 5: The offset is referred to p2000 (reference speed).
If p4810 = 2: In order to avoid the undesirable effects of play (backlash), the offset does not act on the current set-
point, but instead on the speed setpoint.
p4823 Function generator bandwidth / FG bandwith
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0025 [Hz] 16000.0000 [Hz] 4000.0000 [Hz]
p4824 Function generator amplitude / FG amplitude
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-1600.00 [%] 1600.00 [%] 5.00 [%]
p4825 Function generator 2nd amplitude / FG 2nd amplitude
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-1600.00 [%] 1600.00 [%] 7.00 [%]
p4826 Function generator offset / FG offset
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Trace and function generator Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-1600.00 [%] 1600.00 [%] 0.00 [%]