List of parameters
Parameters
1-915
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the actual serial number of the CompactFlash card.
The individual characters of the serial number are displayed in the ASCII code in the indices.
Dependency: Refer to: p9920, p9921
Notice: An ASCII table (excerpt) can be found, for example, in the following List Manual:
Note: Example for displaying a CompactFlash card serial number:
r7843[0] = 49 dec --> ASCII characters = "1" --> serial number, character 1
r7843[1] = 49 dec --> ASCII characters = "1" --> serial number, character 2
r7843[2] = 49 dec --> ASCII characters = "1" --> serial number, character 3
r7843[3] = 57 dec --> ASCII characters = "9" --> serial number, character 4
r7843[4] = 50 dec --> ASCII characters = "2" --> serial number, character 5
r7843[5] = 51 dec --> ASCII characters = "3" --> serial number, character 6
r7843[6] = 69 dec --> ASCII characters = "E" --> serial number, character 7
r7843[7] = 0 dec --> ASCII characters = " " --> serial number, character 8
...
r7843[19] = 0 dec --> ASCII characters = " " --> serial number, character 20
CompactFlash card serial number = 111923E
Description: Displays the software version of the CompactFlash card.
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays whether, for an activated drive object, all activated topology components are available or not (or whether
these can be addressed).
0: Drive object not ready for operation
1: Drive object ready for operation
r7843[0...20] CompactFlash card serial number / CF serial number
CU_S Can be changed: - Calculated: - Access level: 1
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r7844 CompactFlash card software version / CF SW version
CU_S Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r7850[0...15] Drive object operational/not operational / DO ready for oper
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 4
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
-32786 32767 -