EasyManua.ls Logo

Siemens SINAMICS S150 - Page 176

Siemens SINAMICS S150
520 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
6.3 Basic information about the drive system
Drive converter cabinet units
176 Operating Instructions, 07/07, A5E00288214A
Optionally installed drive objects
Option board evaluation
A further drive object handles evaluation of an installed option board. The specific method
of operation depends on the type of option board installed.
Terminal Module evaluation
A separate drive object handles evaluation of the respective optional Terminal Modules.
Configuring drive objects
When you commission the system for the first time using the STARTER tool, you will use
configuration parameters to set up the software-based "drive objects" which are processed
on the Control Unit. Various drive objects can be created within a Control Unit.
The drive objects are configurable function blocks and are used to execute specific drive
functions.
If you need to configure additional drive objects or delete existing ones after initial
commissioning, the drive system must be switched to configuration mode.
The parameters of a drive object cannot be accessed until the drive object has been
configured and you have switched from configuration mode to parameterization mode.
Note
Each installed drive object is allocated a number between 0 and 63 during initial
commissioning for unique identification.
Parameters
p0101 Drive object numbers
r0102 Number of drive objects
p0107 Drive object type
p0108 Drive object configuration

Table of Contents

Other manuals for Siemens SINAMICS S150

Related product manuals