Avoid any uneven stressing when tightening the fastening screws.
Observe the tight
ening torques for the fastening screws.
The general tolerance for the tightening torque is 10%. The tightening torque is based on a
friction coe󹪟cient of μ=0.14.
Motor Screw DIN
7984
Washer ISO 7092 (mm) Tightening torque for screws
(no
t f
or electr
ical connections)
1FL2102
M4 4 (d
2 max
= 8) 2.4 Nm
1FL2☐03
M5 5 (d
2 max
= 9) 4.7 Nm
1FL2104
1FL2204
1FL2205
M6 6 (d
2 max
= 11) 8 Nm
1FL2105
1FL2304
1FL2306
M8 8 (d
2 max
= 15) 20 Nm
1FL2310 M12 12 (d
2 max
= 20) 85 Nm
Tightening torques for the fastening screws
5.2.5 Mounting position
Description
The 1FL2 mot
or supports 󹪞ange mounting only. It can be installed in three orientations as
shown in the following table.
Table 5-5 Type of construction according to IEC60034‑7
Designation Representation Description
IMB5
Standard
IMV1 The motor can be used in types of construction IM V1 and
IMV3 without restriction.
IMV3
Mounting
5.2Motor
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2