Procedure
Proceed as follows to arrange cables in cable carriers:
1. Lay the cables.
Use spacers to separate cables with di󹪜erent outer diameters or cables made of di󹪜erent
materials.
Fill the spacers evenly to ensure that the position of cables does not change during
operation.
Distribute cables symmetrically according to their weights and dimensions.
Keep cables untwisted in the cable carrier.
When inserting prefabricated cables in the cable carrier, do not pull the connector, as this
may damage the strain relief or cable clamping.
2. Move the cables.
Lay the cables loosely in the carrier, so that the cables are free to move in particular in the
bending radii of the carrier.
Observe the speci󹪝ed minimum bending radii.
5
R Bending radius on the cable carrier
3. Fix the cables.
Make sure that cables in t
he carrier are unattached and movable.
Place cable 󹪝xings in a "dead" zone at each end, suitably far away from each end point of
the moving parts.
0RYLQJHQG
'RQRWIL
[WKHFDEOH
DWWKHPRYLQJSDUWV
'RQRWWLHVHYHUDO
FDEOHVWRJHWKHU
)L[HGDWHDFKHQG
)L[LQJHQG
Mounting
5.2Motor
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
118 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA