:LWKRXWDYDULVWRU
:LWKDYDULVWRU
&XUUHQW9ROWDJH
W
W
You may select an appropriate varistor with reference to the table below:
Power supply voltage of the brake 24 V DC
Order information
Manufacturer EPCOS
Model S20K20
Specication r
equire‐
ments
Operating t
emperature -20 °C to 60 °C
Delay switching frequency < 10 times/min
Maximum operating DC voltage 26 V
Average power dissipation 0.2 W
Voltage at 1 mA 33 V ± 10%
Clamping voltage at 20 A (8/20 μs) 65 V
Energy absorption (2 ms) at a time 18 J
Relay (R) used for the power supply of the brake
Siemens recommends that you choose a Siemens r
elay (article number: 3RQ2000-1AW00 or
3RQ2000-2AW00).
You can also select other appropriate relays with reference to the table below:
Insulation voltage for overvoltage category III according to IEC 60664 for
pollution degree 3
300 V
Max. permissible volt
age for protective separation between control cir‐
cuit and auxiliary circuit according to IEC 60947-1
300 V
Contr
ol supply voltage 24 ... 240 AC/DC; 50/60 Hz
Operating range factor of control supply voltage 0.7 ... 1.1
Current-carrying capacity of the output relay
•
At DC-13 at 24 V
2 A
More information
F
or mor
e inf
ormation about cable r
eq
uirements, see Section "Cables and connectors
(Page124)".
For more information about assembling cable terminals, see Section "Assembling cables
(Page734)".
Connecting
6.5Connecting the motor
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2