6.8.2.4 Wiring of analog outputs
Overview
S200 PTI o󹪜ers two analog outputs for transmitting torque and speed signals to the controller.
Connection example
You can connect the analog outputs as shown below:
&RQYHUWHU




$2
$2B0
$2
$2B0
0
0
More information
For more inf
ormation about the technical data of analog outputs, see Section "General technical
data (Page504)".
6.8.2.5 Wiring of pulse train inputs
Overview
The converter o󹪜ers two channels of pulse train inputs:
24V single-end pulse train inputs
The maximum input pulse frequency for the channel is 200kHz.
High-speed 5V di󹪜erential pulse train inputs
The maximum input pulse frequency for the channel is 4MHz.
The channel supports wire-break detection for input pulse frequency up to 1 MHz. When the
converter detects a disconnection in the wire, it outputs fault F07217.
Connecting
6.8Connecting the inputs and outputs
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
154 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA