6.8.2.4 Wiring of analog outputs
Overview
S200 PTI oers two analog outputs for transmitting torque and speed signals to the controller.
Connection example
You can connect the analog outputs as shown below:
&RQYHUWHU
$2
$2B0
$2
$2B0
0
0
More information
For more inf
ormation about the technical data of analog outputs, see Section "General technical
data (Page504)".
6.8.2.5 Wiring of pulse train inputs
Overview
The converter oers two channels of pulse train inputs:
• 24V single-end pulse train inputs
The maximum input pulse frequency for the channel is 200kHz.
• High-speed 5V dierential pulse train inputs
The maximum input pulse frequency for the channel is 4MHz.
The channel supports wire-break detection for input pulse frequency up to 1 MHz. When the
converter detects a disconnection in the wire, it outputs fault F07217.
Connecting
6.8Connecting the inputs and outputs
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
154 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA