7.2.4 Communication interface
Description
The following int
erface is available for accessing the converter:
Interface Information
Service interface X127 The default access to the web server is via the service interface X127.
Service interface X127 is intended for commissioning and diagnostics, which
means that it must alway
s be accessible.
Defaults:
• IP address: 169.254.11.22
• Subne
t mask: 255.255.0.0
• Data transfer via HTTPS is activated in the factory setting.
Restrictions:
• Only local access is allow
ed.
• Only local networking in a closed and locked electrical cabinet is permis‐
sible.
• For remote access to the electrical cabinet, you must apply additional In‐
dustrial Cybersecurity measures to prevent misuse through sabotage, data
manipulation by unqualied persons and interception of condential data.
7.2.5 Making the operating instructions available for the web server information
system
Over
view
For selected topics, you can use the information system of the web server to access the product
documentation directly. To do this, you must make the product documentation available on a
prepared SD card.
Requirement
• You have an empty SD card with a maximum storage capacity of 32GB (e.g.
6SL5570-0GC00-0AA0) onto which you can load the product documentation.
• You have connected a suitable SD card reader to your PC.
Commissioning (web server)
7.2Fundamentals
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 167