Commissioning involves the following steps:
Basic settings:
If the conv
erter has already been commissioned, then the web server jumps to the basic
settings.
The following settings are required for a brand-new converter:
Language, date, time
Security settings:
The settings are con󹪝gured with the help of the Security Wizard.
You can 󹪝nd more information in Section "Security settings (Page174)".
Quick setup:
Menu "Commissioning" > "Quick setup"
Entry or checking of motor and encoder data
PTI and PTO con󹪝guration
Limit values and I/O con󹪝guration
Optimize motor:
Menu "Commissioning" > "Optimization"
The Optimization function measures the mechanical drive train using short test signals and
adapts the controller parameters to the mechanics installed.
Test motor operation:
Action bar > "Control panel"
Test of motor operation using the control panel in jog mode or continuous operation
Backup:
Menu "Backup and restore"
Siemens recommends a backup of the drive settings after commissioning.
More information
For more information about user management and security settings, seeIndustrial
Cybersecurity Con󹪝guration Manual (
https://support.industry.siemens.com/cs/ww/en/view/
109810578).
7.4.2.2 Quick setup
Over
view
The converter can generally be operated without making additional settings using quick setup.
Siemens recommends that you perform the quick setup for the target application.
Requirement
The drive system has been con󹪝gured. The components are wired.
Web server access is active.
Commissioning (web server)
7.4Functions and menus
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
180 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA