For more information about wiring analog inputs, see Section "Connecting the inputs and
outputs (Page147)".
Parameters
The following list includes the parameters of the "Analog inputs" function.
Number Name Unit
r0755[0...1] Analog inputs, actual value in percent [%]
p0756[0...1] Analog inputs type
p0757[0...1] Analog inputs characteristic value x1
p0758[0...1] Analog inputs characteristic value y1 [%]
p0759[0...1] Analog inputs characteristic value x2
p0760[0...1] Analog inputs characteristic value y2 [%]
p0768[0...1] Analog inputs noise suppression window [%]
9.3.4 Analog outputs
Ov
erview
An analog output can output a voltage signal. Based on an adjustable characteristic, the S200
PTI converter converts an internal percentage value into a voltage signal. A signal
interconnection de󹪝nes the function of the analog output.
Description of function
The S200 PTI converter has two analog outputs, AO0 and AO1. The parameter c0771[x] is
assigned to the two analog outputs. You can adjust the function of the analog outputs in
commissioning tools.
The following signals are assignable to the analog outputs.
Parame‐
t
er
Signal Available control mode
F
ast PTI S T
r0063 Actual speed smoothed
r0080 Torque actual value
r0062 Speed setpoint after the 󹪝lt
er
r0079 T
orque setpoint
r0070 Actual DC link voltage
r29350 Pulse input frequency - -
r29351 Remaining number of pulses - -
Functions
9.3Inputs/outputs
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 235