EasyManua.ls Logo

Siemens SINAMICS S200 - One Button Tuning

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.2.1 One Button Tuning
Requirement
NOTICE
Changing t
he controller parameters manually
Manually changing controller parame
ters that were set automatically by One Button Tuning
can result in an unstable controller and therefore material damage.
Do not change the following parameters during One Button Tuning:
p0430, p1160, p1400, p1413 to p1426, p1428, p1429, p1433 to p1435, p1441, p1460 to
p1465, p1498, p1513, p1656 to p1676, p2533 to p2539, p2567, p2572, p2573, p5280,
p29174, p29175, p29176, p29178
Procedure
Proceed as follows t
o perform One Button Tuning with your operating unit:
1. Con󹪝gure the dynamic response setting (p5292).
The higher the dynamic factor, the faster and more unstable the control. You should 󹪝nd a
desired dynamic factor within a resonance-free range.
2. Set the traversing distance for the motor (p5308).
Generally, longer traversing distances result in better tuning results.
3. Con󹪝gure the One Button Tuning function (p5301).
4. Activate the One Button Tuning function (p5300 = 1).
More information
For the detailed One Button Tuning procedures in the web server, see Section "Optimization
(Page185)".
Parameters
The following list includes the parameters of the "One Button Tuning" function.
Number Name Unit
p5271[0].0...7 Online / One Button Tuning con󹪝guration
p5292 FFT tuning dynamic factor [%]
p5300[0] Aut
otuning selection
p5301[0].0...8 One Button Tuning con󹪝gur
ation 2
p5308[0] One Button Tuning dis
tance limiting [°]
Tuning
10.2Autotuning
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 297