10.3 Manual tuning
Overview
When t
he autotuning function cannot achieve your expected tuning results, you can manually
perform tuning.
Description of function
To perform tuning manually, you can disable the autotuning function by setting the parameter
p5300:
p5300 = -1: The autotuning function is disabled and the default values for the speed and
position controller are restored.
p5300 = 0: The autotuning function is disabled and the existing controller parameters are not
changed.
To store the determined values for the speed and position controller retentively, set p0977 =
1 or execute the "Copy RAM to ROM" command.
10.3.1 Control loops
Description
The converter consists of three control loops:
Current control loop
Speed control loop
Position control loop
3RVLWLRQORRS
0RWRU
(QFRGHU
3RVLWLRQ
VHWSRLQW
6SHHGORRS
&XUUHQWORRS
3RVLWLRQ
F
RQWU
ROOHU
6SHHG
FRQWUROOHU
&XUUHQW
FRQWUROOHU
The control loops monitor the feedback of the controlled machines and correct the
commands given to the conv
erter.
Tuning
10.3Manual tuning
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 299