Requirement
You have an SD card with the appropriate 󹪝rmware, or you have an empty SD card with a
maximum capacity of 32GB onto which you can load the 󹪝rmware.
You can download the available 󹪝rmware versions at the following link (https://
support.industry.siemens.com/cs/ww/en/ps/29596/dl).
Procedure
Proceed as follo
ws to update the 󹪝rmware using an SD card:
1. Switch o󹪜 the converter.
2. Insert the SD card into the converter and switch on the converter.
The new 󹪝rmware is installed. This process takes approximately two minutes.
RDY COM Explanation of LED displays
Firmware update is active:
Do not switch o󹪜 the po
wer supply.
Do not disconnect the motor from the converter.
- Firmware update is completed
3. Switch the converter o󹪜 and remove the SD car
d.
4. Switch on the converter again. Check whether the new version is installed. The 󹪝rmware
version of the converter is displayed on the home page of the web server.
More information
You can 󹪝nd more information about the SD card in Section "AUTOHOTSPOT".
12.1.3 Replacing the converter
Overview
You may only replace a converter with another converter if certain requirements are adhered to.
Corrective maintenance
12.1Service and maintenance for the converter
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
484 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA