Technical data
13
13.1 Technical data of the converter
13.1.1
Permissible envir
onmental conditions for the converter
Technical data
Table 13-1 Environmental conditions
Property Description
Environmental conditions for transport in the transport packaging
Climatic environmental conditions
• Surrounding air temperature: -40 °C ... +70°C
Suitable according to Class 2K4 t
o IEC60721‑3‑2
• Humidity: Max. 95% at 45°C according to IEC60721‑3‑2
Mechanical environmental conditions Vibration:
• 2Hz...9Hz: 7.5mm deection
• 9Hz...200Hz: 2g vibration
Vibr
ations permissible according to Class 2M3 to IEC60721-3-2
Protection against chemical substances Protected according to Class 2C2 to IEC60721-3-2
Biological environmental conditions Suitable according to Class 2B2 to IEC60721-3-2
Environmental conditions for long-term storage in the product packaging
Climatic environmental conditions
• Surrounding air temperature: -40°C ... +70°C
•
Relativ
e humidity
: Max. 95%, condensation no
t permis
sible
Mechanical environmental conditions Vibrations permissible according to Class 1M2 to IEC60721-3-1
Protection against chemical substances Protected according to Class 1C2 to IEC60721-3-1
Biological environmental conditions Suitable according to Class 1B2 to IEC60721-3-1
Environmental conditions in operation
Installation altitude
• Up to 2000 m above sea level without power derating
•
Up to 4000m with po
wer derating
Climatic environmental conditions
• Surrounding air temperature:
– for 200 V FSA: 0°C ... 50°C, > 45°C with po
wer derating
– for other converters: 0 °C ... 55 °C, > 45 °C with power derating
• Relative humidity: Max. 95%, condensation not permissible
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 503