Property Description
Mechanical environmental conditions
Shock:
Peak acceleration: 5g
Dur
ation of shock: 30ms
Vibration:
10Hz...58Hz: 0.075mm de󹪞ection
58Hz...200 Hz: 1g vibration
Shocks and vibrations permissible according to Class 3M1 to
IEC60721-3-3
Protection against chemical substances Protected according to Class 3C2 to IEC60721-3-3
Biological environmental conditions Suitable according to Class 3B1 to IEC60721-3-3
Pollution Suitable for environments with degree of pollution 2 according to
IEC61800-5-1
13.1.2 General technical data
Technical data
Table 13-2
General technical data of the converter
Parameter Description
Overload capability 350% overload: for 200 V and 400 V variants with a power rating of 0.1 kW to 0.75 kW
300% overload: for 200 V and 400 V v
ariants with a power rating of 1 kW to 7 kW
Output frequency (Hz) 0 ... 550
IGBT pulse frequency without derat‐
ing (kHz)
8
Control system Servo control
Dynamic brake Integrated
Protective functions Grounding fault protection, output short-circuit protection
1)
,
overv
oltage/undervoltage
protection
2)
, converter I
2
t protection, motor overtemperature protection
3)
, IGBT over‐
temperature protection
Surge voltage Ful󹪝ll the requirement of the standard IEC61800-3
Overvolt
age category Category III according to IEC 61800-5-1
Minimum prospective short‑circuit
cur
rent
To pre
vent 󹪝re in the event of a fault, a minimum value must be ensured for the pro‐
spective short-circuit current so that the upstream protective device trips quickly
enough. A typical value when dimensioning is 20 to 25 times
4)
the rated current of the
protection device used.
Maximum permissible short-circuit
current (SCCR, kA rms)
For 200 V v
ariants: 100
5)
For 400 V variants: 65
Cooling type
For 200 V variants: Natural cooling
For 400 V variants:
FS
A and FSB: Natural cooling
FSC and FSD: Fan cooling
Technical data
13.1Technical data of the converter
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
504 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA

Table of Contents

Other manuals for Siemens SINAMICS S200

Related product manuals