Parameter Description
Degree of protection according to
IEC60529
IP20
Mains supply
Permissible mains supply network TN, TT, IT
Line voltage 1 AC/3 AC 200 V ... 240 V
3 A
C 380 V ... 480 V
Line frequency (Hz) 50/60
Permis
sible line voltage uctuation -15% ... +10%
Permissible line frequency uctua‐
tion
-10% ... +10%
24 V DC power supply
Voltage (V) 24 (-15% ... +20%)
6)
Permissible voltage uctuation (V) When using a motor without brake: 20.4 ... 28.8
When using a mo
tor with brak
e: 22.8 ... 28.8
Maximum current (A)
• For 200 V variants:
– When using a motor without a br
ake: 1.2
– When using a motor with a brake: 2.2
• For 400 V variants:
– When using a motor without a brake: 1.2
– When using a motor with a brake: 3.2
Safety insulation class SELV
Speed control mode
Speed control range Analog speed command 1:2000, internal speed command 1:5000
Analog speed command input -10VDC to +10VDC/rated speed
Torque limit Set through a parameter or the analog input command (0 V DC to +10 V DC/maximum
t
orque)
Position contr
ol mode
Maximum input pulse frequency 4 M (dier
ential input), 200 kpps (open collector input)
Command pulse multipl
ying factor Recommended electronic gear ratio (A/B)
A: 1 - 10000, B: 1 - 10000
1/1000 < A/B < 64000
In-position range setting 0 to 2147483647 pulse (command pulse unit)
Error excessive ±1/10 revolutions
Torque limit Set through a parameter or the analog input command (0 V DC to +10 V DC/maximum
t
orque)
Tor
que control mode
Analog torque command input -10VDC to +10VDC/maximum torque (input impedance 10kΩ to 12kΩ)
Speed limit Set through a parameter or the analog input command (0 V DC to +10 V DC/maximum
speed)
Inputs and outputs
Technical data
13.1Technical data of the converter
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 505