Article No. 6SL5☐10-1BB 10-4AA0
Fuse according to IEC 3NA3801 (6 A)
3NW6301-1 (6 A)
Fuse according to UL, ClassJ 6A
Leakage current (mA) 1 AC 21
3 AC 24
Outline dimensions (W x H x D, mm) 40 x 170 x 170
Weight (g) S200 PTI 1028.9
S200 Basic PTI 960
Table 13-5 Specic technical data of 200 V conv
erters frame size C
Article No. 6SL5☐10-1BB 10-8AA0 11-0AA0
Frame size FSC FSC
Rated input current (A) 1 AC 7.0 8.0
3 AC 3.5 4.0
Rated output current (A) 4.4 4.4
Maximum output current (A) 16.8 16.8
Maximum supported motor power (kW) 0.75 1.0
Power loss (W) 45 46
Inrush current (A) 7.6 7.6
Fuse according to IEC 3NA3805 (16A) 3NA3805 (16A)
3NW6006-1 (12 A) 3NW6006-1 (12 A)
Fuse according to UL, ClassJ 15A 15A
Leakage current (mA) 1 AC 20 20
3 AC 23 23
Outline dimensions (W x H x D, mm) 60 x 170 x 195 60 x 170 x 195
Weight (g) S200 PTI 1741.4 1741.4
S200 Basic PTI 1741.4 1741.4
13.1.4 Specic data of the 400 V conver
ters
Technical data
Table 13-6 Specic technical data of 400 V converters frame size A
Article No. 6SL5510-1BE 10-2AA0 10-4AA0
Frame size FSA FSA
Rated input current (A) 1.3 1.3
Rated output current (A) 1.3 1.3
Maximum output current (A) 5.1 6.0
Technical data
13.1Technical data of the converter
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
508 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA