Article No. 6SL5510-1BE 10-2AA0 10-4AA0
Maximum supported motor power (kW) 0.2 0.4
Power loss (W) 31 32
Inrush current (A) 7.5 7.5
Fuse according to IEC 3NA3804 (4 A) 3NA3804 (4 A)
3NW6304-1 (4 A) 3NW6304-1 (4 A)
Fuse according to UL, ClassJ 3A 3A
Leakage current (mA) 36 36
Outline dimensions (W x H x D, mm) 50 x 180 x 200 50 x 180 x 200
Weight (g) 1517.5 1517.5
Table 13-7 Specic technical data of 400 V conv
erters frame size B
Article No. 6SL5510-1BE 10-8AA0 11-0AA0
Frame size FSB FSB
Rated input current (A) 2.5 3.0
Rated output current (A) 2.5 3.0
Maximum output current (A) 9.3 11.5
Maximum supported motor power (kW) 0.75 1.0
Power loss (W) 46 54
Inrush current (A) 7.5 7.5
Fuse according to IEC 3NA3803 (10 A) 3NA3803 (10A)
3NW6303-1 (10 A) 3NW6303-1 (10 A)
Fuse according to UL, ClassJ 10A 10A
Leakage current (mA) 39 39
Outline dimensions (W x H x D, mm) 60 x 180 x 200 60 x 180 x 200
Weight (g) 1912.4 1912.4
Table 13-8 Specic technical data of 400 V conv
erters frame size C
Article No. 6SL5510-1BE 11-5AA0 12-5AA0
Frame size FSC FSC
Rated input current (A) 5.5 8.0
Rated output current (A) 5.3 7.8
Maximum output current (A) 20 26.5
Maximum supported motor power (kW) 1.75 2.5
Power loss (W) 84 123
Inrush current (A) 15 15
Fuse according to IEC 3NA3805 (16A) 3NA3805 (16A)
3NW6006-1 (12 A) 3NW6305-1 (16 A)
Fuse according to UL, ClassJ 15A 20A
Leakage current (mA) 46 46
Technical data
13.1Technical data of the converter
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 509