EasyManua.ls Logo

Siemens SINAMICS S200 - Page 523

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor Steel plate: width x height x thickness (mm)
1FL2306 390 x 390 x 15
1FL2310 420 x 420 x 20
The data in the table refers to an ambient temperature of +40°C and an installation altitude
up to 1000m above sea lev
el. If the environmental conditions are di󹪜erent, derating may be
required. You can 󹪝nd information on this in Section "Derating factors (Page521)".
Larger mounting surfaces improve heat dissipation.
Thermally insulated mounting without additional mounted components
For naturally cooled motors, you must reduce the S1-characteristic curve as follows:
Reduce the motor static torque by a range of 20% to 30%.
Reduce the torque at 3000r/min by a range of 40% to 50%.
Thermal motor protection
The converter monitors the motor temperature based on a thermal motor model and issues
the alarm "Motor overtemperature" before the maximum temperature is reached. If the
motor exceeds the maximum temperature, the converter switches o󹪜 the motor with the
fault message "Motor overtemperature".
If the ambient temperature exceeds 40°C, you need to set the ambient temperature at the
converter so that the motor is reliably protected.
To do this, select parameter p0613 at the converter.
Set the maximum ambient temperature that occurs.
Parameter r0034 indicates the thermal load of the motor as a percentage. The reading is
in󹪞uenced by the ambient temperature selected in parameter p0613.
You can 󹪝nd additional information in Section "Parameter list (Page589)".
13.2.5 Derating factors
Overview
Due to the decreasing air pressure in higher installation altitudes, the cooling of the motor
deteriorates. Therefore, reduce the power of the motor as the installation altitude increases.
Multiply the permissible torques or powers by the factors from the following table.
Reduce the torques and powers according to the values determined.
Technical data
13.2Technical data of the motor
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 521

Table of Contents

Other manuals for Siemens SINAMICS S200

Related product manuals