Limited EMERGENCY STOP operation is permissible. Take into account the maximum
permissible single operating energy as w
ell as service life, total operating energy of the
brake.
WARNING
Unintentional movements through inadequate braking eect
If you use t
he holding brake incorrectly, for example, as an operating brake or you ignore the
permissible operating energy of the brake, then the brake will be subject to excessive and
impermissible wear. As a consequence, there may be no brake eect. Unintentional
movements of the machine or system can result in death or serious injury.
• Observe the permissible number of operating cycles and EMERGENCY STOP properties.
• Operate the motor only in conjunction with an intact brake.
• Avoid repeated brief acceleration of the motor against a holding brake that is still closed.
The holding brakes of the 1FL2 have a torsional backlash of less than 1°.
13.2.13.2 Technical data of t
he 1FL2 holding brake
Technical data
Table 13-27 Technical data of the holding brake
Motor type Holding tor‐
q
ue
Dynamic
braking t
or‐
q
ue
Opening
time
Closing time
Maximum
permis
sible
single oper‐
ating ener‐
gy
1)
Total operat‐
ing energy
(service life)
Holding
current
M
4
/ Nm M
1m
/ Nm t
open_f
/ ms t
close_f
/ ms W
max
/ J W
tot
/ kJ I
h
/ A
Permanent-magnet br
ake
1FL2☐05 8 5 90 25 142 284 < 1 A
Spring-loaded brake
1FL2102 0.32 - 35 10 1 2 < 1 A
1FL2☐03 1.3 - 60 10 10 20 < 1 A
1FL2104
1FL2204
3.3 - 110 30 43 86 < 1 A
1FL2304 3.5 - 60 45 140 280 < 2 A
1FL2306 12 180 60 600 1200 < 2 A
1FL2310 30 - 220 115 1100 2200 < 2 A
1)
Maximum of t
hr
ee consecutiv
e EMER
GENCY S
TOP procedures. Maximum25% of all EMERGENCY STOP procedures as high-
energy stops with W
max
.
Holding torque M
4
: The holding torque M
4
is the highest permissible torque for the closed
brake in steady-state operation without slip (holding function when motor is at standstill).
The data applies to the state at operating temperature (120°C).
Technical data
13.2Technical data of the motor
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
536 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA