Dynamic braking torque M
1m
: The dynamic braking torque M
1m
is t
he smallest mean
dynamic braking torque that can occur for an EMERGENCY STOP.
Opening time t
o
and closing time t
cl
: The delay times that occur when switching the
brake t
o
and t
cl
are saved in the motor and are automatically taken into consideration. After
activation of the holding brake (opening), the speed/velocity setpoint remains at "Zero"
during the opening time t
o
. The speed/velocity setpoint is only enabled after the opening
time t
o
has elapsed. After OFF1 or OFF3 and activation of the holding brake (closing), the
motor still remains in closed-loop control with speed/velocity setpoint "Zero" during closing
time t
cl
. The pulses are only deleted after this.
Maximum permissible single operating energy W
max
: The maximum permissible single
operating energy of an individual EMERGENCY STOP operation. After an EMERGENCY STOP
with the maximum single operating energy, allow a cooling time of at least threeminutes
before you operate the motor again.
Total operating energy (service life) W
total
: The total operating energy is the sum of the
single operating energy (operating energy for each EMERGENCY STOP procedure). If you
exceed the total operating energy, problem-free functioning of the brake can no longer be
guaranteed.
Holding current I
h
: The holding current I
h
keeps the holding brake open. The holding current
I
h
continues to load the 24V power supply of the converter after overexcitation until the
brake is released.
Formula to calculate the operating energy per braking operation
W
br
=(J
mot br
+J
load
)•n
mot
²/182.4
W
br
/ J Operating energy per braking operation
n
mot
/ r/min Speed at which the brake is engaged
J
mot br
/ kgm
2
Rotor
moment of inertia of the motor with brake (see Technical data and char‐
acteristics of the 1FL2 (Page537))
J
load
/ kgm
2
Load moment of inertia of the mounting part on t
he motor with brake
182.4 Constant for calculating the circular frequency and SI units
13.2.14 Technical data and characteristics of the 1FL2
13.2.14.1 1FL2102-2AG connected to 1 A
C 200 V/3 AC 220 V
Technical data
Table 13-28 Technical data of 1FL2102‑2AG
Feature Symbol Unit Value
Static torque M
0
Nm 0.16
Stall current I
0
A 0.81
Maximum permissible speed n
max
r/min 6500
Technical data
13.2Technical data of the motor
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 537