Loading...
Property MOTION-CONNECT 350
power cable
MOTION-CONNECT 350 en‐
coder cable
MO
TION-CONNECT 350
brake cable
Minimum bending radius, dy‐
namic (mm)
7.5 x outer diameter 7.5 x outer diameter 7.5 x outer diameter
Maximum acceleration (m/s
2
) 3 3 3
Maximum traversing velocity
(m/min)
1FL2 0.4kW...2kW:40
1FL2 2.5kW:50
1FL2 3.5 kW...7kW:50
40 50
13.3.2 Technical data of MOTION-CONNECT 380
13.3.2.1 General technical dat
a
Technical data
Table 13-66 General technical data of MOTION-CONNECT 380
Property MOTION-CONNECT 380
po
wer cable
MOTION-CONNECT 380 en‐
coder cable
MO
TION-CONNECT 380
brake cable
Jacket material PUR PUR PUR
Number of conductors
With brake conductors:6
Without brak
e conduc‐
tors:4
6 2
Operating temperature (°C) -20...+80 -20...+80 -20...+80
Shielding Braided shield;
co
verage ≥ 85%
Br
aided shield;
coverage ≥ 85%
Braided shield;
coverage ≥ 85%
Oil resistance EN60811-2-1 EN60811-2-1 EN60811-2-1
Flame retardancy EN60332-1-1 to 1-3 EN60332-1-1 to 1-3 EN60332-1-1 to 1-3
Coolant resistance EN60811-2-1 EN60811-2-1 EN60811-2-1
Degree of protection (motor-
side onl
y)
IP65 IP65 IP65
Bending cycles 5 million 5 million 5 million
Rated v
oltage U
0
/U (V)
200V converters:
300/1000
400V convert
ers:
600/1000
30/300 30/300
Technical data
13.3Technical data of MOTION-CONNECT cables
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 575