Index: [0] = Inverter maximum value
[1] = Depletion layer maximum value
[2] =
Recti󹪝er maximum value
[3] = Air intake
[4] = Interior of power unit
[5] = Cooling unit liquid intake
[6] = Capacitor air discharge
[7] = Depletion layer maximum value 1
[8] = Depletion layer maximum value 2
[9] = Depletion layer maximum value 3
[10] = Depletion layer maximum value 4
Note
The value of -200 indicates that ther
e is no measuring signal.
r0037[0]: Maximum value of the inverter temperatures.
r0037[1]: Maximum value of the depletion layer temperatures.
In the case of a fault, the particular shutdown threshold depends on the power unit, and cannot be read out.
r0039[0...2] Energy display
Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Mode signals / displays, Power loss optimization
Unit: kWh
Description: Display for the energy values at the drive output terminals.
Index: [0] = Energy balance (sum)
[1] = Energy drawn
[2] = Energy f
ed back
Note
For index [0]:
Di󹪜erence betw
een the energy drawn and energy that is fed back.
r0044 Thermal converter utilization
Data type: FloatingPoint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Mode signals / displays, Power unit
Unit: %
Description: Displays the thermal converter utilization as a percentage.
With this value, v
arious thermal monitoring functions are taken into account.
Dependency: See also: r0034
Note
The thermal motor utilization is display
ed in parameter r0034.
r0046.0...30 Missing enable signals
Data type: U
nsigned32 V
isible in: S
t
andar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or drive applications
Parame
ter group: Control/status words, Drive enable signals
Unit: -
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 593