p29342 Reference frequency assigned to pulse input frequency
S200 PTI Data type: Integer16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Ready for oper
ation
Parameter group: Technology Extensions, Position monitoring
Unit: -
Min:
1
Max:
4
Factory setting:
1
Description: Sets the reference frequency of the pulse input frequency.
1: reference 1k
2: ref
erence 10k
3: reference 100k
4: reference 1000k
Value: 1: Pulse input frequency (reference 1k)
2: Pulse input frequency (reference 10k)
3: Pulse input frequency (reference 100k)
4: Pulse input frequency (reference 1000k)
p29343 Reference frequency assigned to remaining number of pulses
S200 PTI Data type: Int
eger16 Visible in: St
andard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Can be
changed in the operating
state:
Ready for oper
ation
Parameter group: Technology Extensions, Position monitoring
Unit: -
Min:
1
Max:
4
Factory setting:
1
Description: Sets the reference frequency of the remaining number of pulses.
1: reference 1k
2: ref
erence 10k
3: reference 100k
4: reference 1000k
Value: 1: Remaining number of pulse (reference 1k)
2: Remaining number of pulses (reference 10k)
3: Remaining number of pulses (reference 100k)
4: Remaining number of pulses (reference 1000k)
r29350 Pulse input frequency
S200 PTI Data type: FloatingP
oint32 Visible in: Standar
d display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or drive applications
Parame
ter group: Technology Extensions, Position monitoring
Unit: -
Description: Displays the pulse input frequency.
Appendix
A.3Parameters
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
730 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA