12.Insert the gaskets and the clamps to the seal case.
DE
13.Tighten the caps.
Rotate t
he caps in the counterclockwise direction to match the threads of the seal case
and the caps.
Rotate the caps in the clockwise direction.
Tighten the caps by wrench with a tightening torque of 1.5 Nm ± 0.01 Nm.
1P1P
DFE
More information
For more inf
ormation about connecting the converter and the motor, see Section "Connecting
the motor (Page129)".
A.4.2.2 Disassembling the hybrid plug for 1FL2 motors, shaft heights 20, 30, and 40
Requirement
You have prepared the following items:
Assembled Siemens hybrid plug
Pin removal tool
Screwdriver
Appendix
A.4Assembling cables
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
746 Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA

Table of Contents