7.5 Faults
Faults
Faults have the following properties:
The fault causes the motor to be switched off.
Faults must be acknowledged.
Faults are displayed as follows:
In the PLC according to the PROFIdrive message class
On the drive via LEDs
At the drive using the three-digit display according to the PROFIdrive message classes
In the Web server via the "Diagnostics - Messages" view
Acknowledge fault
Before you can acknowledge a fault, you must have resolved the cause of the fault.
To acknowledge, you have the following options:
Acknowledging via the PLC
Acknowledging via the OK button under the front cover
Switch off the converter power supply and switch on again
Acknowledging via the Web server
Faults detected during the converter-internal monitoring of hardware and firmware can be
acknowledged only by switching the power supply off and on again. In the list of faults, you
will find the information on limitations when acknowledging at the corresponding fault codes.
Reference
You can find additional information on faults in Chapter "Overview of faults and alarms
(Page 291)".