EasyManua.ls Logo

Siemens SINAMICS V10 - Page 86

Siemens SINAMICS V10
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Par. No. Name Range Default Unit
P0731 Function of digital output 1 0.0 - 2036.F 52.2 --
Defines source of digital output 1.
Possible settings:
0 Open
1 Closed
52.0
...
52.F
See parameter r0052 for the meaning of individual value settings.
Note:
The meaning of 52.0 corresponds to the description of Bit00, The meaning of 52.1 corresponds to
the description of Bit01, the rest on the analogy of it.
722.0 ...
722.2
See parameter r0722 for the meaning of individual value settings.
Note:
The meaning of 722.0 corresponds to the description of Bit00, The meaning of 722.1 corresponds
to the description of Bit01, the rest on the analogy of it.
2036.0 .
..
2036.F
See parameter r0236 for the meaning of individual value settings.
Note:
The meaning of 2036.0 corresponds to the description of Bit00, The meaning of 2036.1 corresponds
to the description of Bit01, the rest on the analogy of it.
P0748 Invert digital outputs 0 - 1 0 --
Defines high and low states of relay for a given function.
Bitfields:
Bit00 Invert digital output 1 0 NO 1 YES
Note:
The 7-segment display of the bit-parameters (binary parameters) is explained in Fig. 6-2 of Chapter 6.
r0752 Act. input of ADC [V] -- -- --
Displays smoothed analog input value in volts before the characteristic block.
P0753 Smooth time ADC 0 - 10,000 300 ms
Defines filter time (PT1 filter) in [ms] for analog input.
Note:
Increasing this time (smooth) reduces jitter but slows down responses to the analog input.
P0753 = 0: No filtering
Parameter list
SINAMICS V10
86 Operating Instructions, 08/2011, A5E03453178 (this is not an order number)

Table of Contents

Related product manuals