Parameter list
SINAMICS V20 Inverter
52 Getting Started, 07/2012, A5E03728127
Parameter Description Range Factory default Acc. level
P0775[0] Permit absolute value 0 - 65535 0 2
P0777[0] Value x1 of analog output scaling [%] -99999 - 99999 0.0 2
P0778[0] Value y1 of analog output scaling 0 - 20 0 2
P0779[0] Value x2 of analog output scaling [%] -99999 - 99999 100.0 2
P0780[0] Value y2 of analog output scaling 0 - 20 20 2
P0781[0] Width of analog output deadband 0 - 20 0 2
r0785.0 CO / BO: Status word of analog output - - 2
P0809[0...2] Copy command data set (CDS) 0 - 2 [0] 0 [1] 1 [2] 0 2
Index: [0] Copy from CDS
[1] Copy to CDS
[2] Start copy
P0810 BI: command data set bit 0 (Hand / Auto) - 0 2
P0811 BI: command data set bit 1 - 0 2
P0819[0...2] Copy inverter data set (DDS) 0 - 2 [0] 0 [1] 1 [2] 0 2
Index: [0] Copy from DDS
[1] Copy to DDS
[2] Start copy
P0927 Parameter changeable via - 1111 bin 2
r0947[0...63] CO: Last fault code - - 2
P0970 Factory reset 0 - 21 0 1
0 Disabled
1 Parameter reset
21 User Default Parameter Reset
P1000[0...2] Selection of frequency setpoint 0 - 77 1 1
0 No main setpoint 30 No main setpoint + Fixed frequency
1 MOP setpoint 31 MOP setpoint + Fixed frequency
2 Analog setpoint 32 Analog setpoint + Fixed frequency
3 Fixed frequency 33 Fixed frequency + Fixed frequency
5 USS on RS485 35 USS on RS485 + Fixed frequency
7 Analog setpoint 2 37 Analog setpoint 2 + Fixed frequency
10 No main setpoint + MOP setpoint 50 No main setpoint + USS on RS485
11 MOP setpoint + MOP setpoint 51 MOP setpoint + USS on RS485
12 Analog setpoint + MOP setpoint 52 Analog setpoint + USS on RS485
13 Fixed frequency + MOP setpoint 53 Fixed frequency + USS on RS485
15 USS on RS485 + MOP setpoint 55 USS on RS485 + USS on RS485
17 Analog setpoint 2 + MOP setpoint 57 Analog setpoint 2 + USS on RS485
20 No main setpoint + Analog setpoint 70 No main setpoint + Analog setpoint 2
21 MOP setpoint + Analog setpoint 71 MOP setpoint + Analog setpoint 2
22 Analog setpoint + Analog setpoint 72 Analog setpoint + Analog setpoint 2
23 Fixed frequency + Analog setpoint 73 Fixed frequency + Analog setpoint 2
25 USS on RS485 + Analog setpoint 75 USS on RS485 + Analog setpoint 2
27 Analog setpoint 2 + Analog setpoint 77 Analog setpoint 2 + Analog setpoint 2