Technical specifications
SINAMICS V20 Inverter
64 Getting Started, 07/2012, A5E03728127
Environmental conditions
Ambient temperature 0 ... 40 °C: without derating
40 ... 60 °C: with derating
Storage temperature -40 ... + 70 °C
Protection class IP 20
Maximum humidity level 95 % (non-condensing)
Long-term storage in the transport packaging according to EN 60721-3-1 Class 1M2
Transport in the transport packaging according to EN 60721-3-2 Class 2M3
Shock and vibration
Vibration during operation according to EN 60721-3-3 Class 3M2
Operating altitude Up to 4000 m above sea level
1000 ... 4000 m: output current derating
2000 ... 4000 m: input voltage derating
Environmental classes Pollution class: 3S2
Gas class: 3C2 (SO
2
, H
2
S)
Climate class: 3K3
Minimum mounting clearance Top: 100 mm
Bottom: 100 mm (85 mm for fan-cooled frame size A)
Side: 0 mm
Standards
European Low Voltage Directive (EN61800 -5-1 and EN 60204-1)
CE marking
European EMC Directive (EN 61800 - 3)
UL certification (UL508C)
CTick marking
ISO 9001