Getting Started
102 A5E37208904-003, 04/2017
p29025 Tuning: Configuration
Overall configuration of auto tuning, apply for both one-button and real-time auto tuning.
• Bit 0: For significant differences between the motor and load moment of inertia, or for low dynamic perfor-
mance of the controller, then the P controller becomes a PD controller in the position control loop. As a
consequence, the dynamic performance of the position controller is increased. This function should only
be set when the speed pre-control (bit 3 = 1) or the torque pre-control (bit 4 = 1) is active.
• Bit 1: At low speeds, the controller gain factors are automatically reduced in order to avoid noise and oscil-
lation at standstill. This setting is recommended for incremental encoders.
• Bit 2: The estimated load moment of inertia is taken into account for the speed controller gain.
• Bit 3: Activates the speed pre-control for the position controller.
• Bit 4: Activates the torque pre-control for the position controller.
•
Bit 5: Adapts acceleration limit.
p29026 Tuning: Test signal dura-
Description: The duration time of the one-button auto tuning test signal.
p29027 Tuning: Limit rotation of
The limit position with motor rotations during one-button auto tuning. The traversing range is
limited within +/- p29027 degrees (motor run one revolution is 360 degree).
p29028 Tuning: Pre-control time
0.0 60.0 7.5 ms Float IM T, U
Sets the time constant for the pre-control symmetrization for auto tuning.
As a consequence, the drive is allocated a defined, dynamic response via its pre-control.
For drives, which must interpolate with one another, the same value must be entered.
The higher this time constant is, the smoother the drive will follow the position set point.
This time constant is only effective when multi-axis interpolation is selected (bit 7 of p29023 and
Select the VIBSUP ON/OFF.
Position setpoint filter can be activated (p29035) for EPOS control mode.
• 0: Disable
Filter is not activated.
• 1: Enable
Positive torque limit.
Two internal torque limits in total are available.
You can select the internal parameters as the source of the torque limit with the digital input signals TLIM.
Negative torque limit.
Two internal torque limits in total are available.
You can select the internal parameters as the source of the torque limit with the digital input signals TLIM.
Positive speed limit.
Two internal speed limits in total are available.
You can select the internal parameters as the source of the speed limit with the digital input signals SLIM.