Getting Started
90 A5E37208904-003, 04/2017
Par. No.
Name
Min
Max
Factory
Setting
Unit
Data
type
Effective
Can be
changed
p1656 * Activates current setpoint
filter
- - 0001
bin
- U16 IM T, U
Description:
Setting for activating/de-activating the current setpoint filter.
Bit 0: Activate filter 1
Bit 0 = 0: Deactivated
Bit 0 = 1: Activated
Bit 1: Activate filter 2
Bit 1 = 0: Deactivated
Bit 1 = 1: Activated
Bit 2: Activate filter 3
Bit 2 = 0: Deactivated
Bit 2 = 1: Activated
Bit 3: Activate filter 4
Bit 3 = 0: Deactivated
Bit 3= 1: Activated
Dependency: The individual current setpoint filters are parameterized as of p1658.
Note:
If not all of the fil
ters are required, then the filters should be used consecutively starting from filter 1. The
drive unit displays the value in hex format. To know the logic (high/low) assignment to each bit, you must
convert the hex number to the binary number, for example, FF (hex) = 11111111 (bin).
p1658 * Current setpoint filter 1
denominator natural fre-
quency
0.5 16000.0 1999.0 Hz Float IM T, U
Description: Sets the denominator natural frequency for current setpoint filter 1 (PT2, general filter).
Dependency: The current setpoint filter 1 is activated via p1656.0 and parameterized via p1658 ... p1659.
p1659 * Current setpoint filter 1
denominator damping
0.001 10.000 0.700 - Float IM T, U
Description: Sets the denominator damping for current setpoint filter 1.
Dependency: The current setpoint filter 1 is activated via p1656.0 and parameterized via p1658 ... p1659.
p1663 Current setpoint filter 2
denominator natural fre-
quency
0.5 16000.0 1000.0 Hz Float IM T, U
Description: Sets the denominator natural frequency for current setpoint filter 2 (PT2, general filter).
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1664 Current setpoint filter 2
denominator damping
0.001 10.000 0.300 - Float IM T, U
Description: Sets the denominator damping for current setpoint filter 2.
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1665 Current setpoint filter 2
numerator natural fre-
quency
0.5 16000.0 1000.0 Hz Float IM T, U
Description: Sets the numerator natural frequency for current setpoint filter 2 (general filter).
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1662 ... p1666.
p1666
Current setpoint filter 2
numerator damping
0.000 10.000 0.010 - Float IM T, U
Description: Sets the numerator damping for current setpoint filter 2.
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.