Getting Started
A5E37208904-003, 04/2017
91
Par. No.
Name
Min
Max
Factory
Setting
Unit
Data
type
Effective
Can be
changed
p1668 Current setpoint filter 3
denominator natural fre-
quency
0.5 16000.0 1000.0 Hz Float IM T, U
Description: Sets the denominator natural frequency for current setpoint filter 3 (PT2, general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1669 Current setpoint filter 3
denominator damping
0.001 10.000 0.300 - Float IM T, U
Description: Sets the denominator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1670 Current setpoint filter 3
numerator natural fre-
quency
0.5 16000.0 1000.0 Hz Float IM T, U
Description: Sets the numerator natural frequency for current setpoint filter 3 (general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1671 Current setpoint filter 3
numerator damping
0.000 10.000 0.010 - Float IM T, U
Description: Sets the numerator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1673 Current setpoint filter 4
denominator natural fre-
quency
0.5 16000.0 1000.0 Hz Float IM T, U
Description:
Sets the denominator natural frequency for current setpoint filter 4 (PT2, general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1674 Current setpoint filter 4
denominator damping
0.001 10.000 0.300 - Float IM T, U
Description: Sets the denominator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1675 Current setpoint filter 4
numerator natural fre-
quency
0.5 16000.0 1000.0 Hz Float IM T, U
Description: Sets the numerator natural frequency for current setpoint filter 4 (general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1676 Current setpoint filter 4
numerator damping
0.000 10.000 0.010 - Float IM T, U
Description: Sets the numerator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p2000
Reference speed
6.00
210000.00
3000.00
rpm
Float
IM
T
Description:
Sets the reference quantity for speed and frequency.
All speeds or frequencies specified as relative value are referred to this reference quantity.
The reference quantity corresponds to 100% or 4000 hex (word) or 40000000 hex (double word).
Dependency:
Refer to: p2003
p2002 Reference current 0.10 100000.00 100.00 Arm
s
Float IM T
Description
: Sets the reference quantity for currents.
All currents specified as relative value are referred to this reference quantity.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).