EasyManua.ls Logo

Siemens SINAMICS V90 - Page 154

Siemens SINAMICS V90
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Task navigation
SINAMICS V-ASSISTANT Online Help
154 Operating Manual, 04/2017, A5E36618042-003
Byte
Description
User data
0001 h
2F1A h
8002 h
0202 h
1001 h
0461 h
0000 h
1001 h
71CA h
0000 h
0801 h
4134 h
7AE1 h
0301 h
0002 h
7,8
9,10
11,12
13,14
15,16
17,18
19,20
21,22
23,24
25,26
27,28
29,30
31,32
33,34
35,36
40601: ds47=1 (activate request)
40602: Function 2F h (47), request length 16 bytes (10 h)
40603: Request reference = 80 h, request identifier = 2 h (write)
40604: V90 = 2 h, number of parameters = 2
40605: Attribute, number of elements of the first parameter
40606: First parameter number = p1121
40607: First parameter subindex = 0
40608: Attribute, number of elements of the second parameter
40609: Second parameter number = p29130
40610: Second parameter subindex = 0
40611: Format, number of values of the first parameter
40612: First parameter value 11.28 (41347AE1 h)
40613: First parameter value
40614: Format, number of values of the second parameter
40615: Second parameter value 2
Write the PLC command from registers 40601 to 40615:
The table below formats a response for successful write operation.
Table 4- 1 Response for successful write operation
Byte
Description
Header
01 h
03 h
20 h
0
1
2
Slave address
Function code (read)
Number of following data bytes (20 h: 32 bytes 16 registers)
User data
0002 h
2F04 h
8002 h
0202 h
3,4
5,6
7,8
9,10
40601: DS47 Control = 2 (request was executed)
40602: Function code 2F h (47), response length 4 bytes
40603: Request reference mirrored = 80 h,
response identifier = 2 (change parameter)
40604: V90 = 2 h, number of parameters = 2

Table of Contents