Installing and putting a SINAUT modem into operation
5.7 Analog dial-up modem MD3
Station control system
System Manual, 07/2009, C79000-G8976-C178-07
233
5.7.2 Configuration switches accessible from above
The following figure shows the MD3 modem from above. It indicates the location of the SW1
(4-pin) and SW2 (10-pin) DIL switches that are accessible from above.
1 2 3 4 5 6 7 8 9 10
1 2 3 4
6:
6:
SLQ6:',/VZLWFKIRUVHWWLQJWKH
PHWHULQJSXOVHILOWHUDQGIRUGHDFWLYD
WLQJWKHORRSSRZHUVHFWLRQIRU
GHGLFDWHGOLQHPRGH
SLQ6:',/VZLWFKIRUVHWWLQJWKH
UHTXLUHGGLDOXSQHWZRUNRUGHGLFDWHG
OLQHPRGH
)URQWSDQHOODEHOHGಪ0RGHPಫ
Figure 5-29 View of the MD3 modem from above
Settings with the DIL switches accessible from above
The MD3 modem has a 4-pin and a 10-pin DIL switch. The 10-pin DIL switch, SW2 is
located directly on the top housing grill. The 4-pin DIL switch, SW1, can also be reached
from above through the housing grill, however it is located deeper within the housing and
may therefore be more difficult recognize. To set this switch, you require a long, thin tool, for
example a small screwdriver or a toothpick.
The DIL switches have the following functions:
4-pin DIL switch SW1
Metering pulse filter
at 12 kHz or at 16 kHz
Activating or deactivating the loop power section