EasyManua.ls Logo

Siemens SINAUT ST7 - Point-To-Point with Fiber Optic Section, 2-Wire Half-Duplex (RS485 Interface)

Siemens SINAUT ST7
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network Configurations
© Siemens AG 2002 All Rights Reserved 6NH7811-0AA22
MD2 Modem (07/2002) 5-35
5.2.2 Point-to-Point with Fiber Optic Section, 2-wire Half-duplex
(RS485 Interface)
Fig. 5-11 shows a configuration for a point-to-point connection with fiber optic
section, 2-wire half-duplex. Both MD2 modems represent 2-wire terminal points
and are set to the "With RS485 interface" operating mode. In addition a fiber optic
section is connected through the RS485 interface of one of the MD2 modems.
All available baud rates and character recognition methods except for "MID off" can
be used in this configuration.
The DIL switch settings on the MD2 modem and the switch settings on the LTOP1
are the same at both terminal points (see Table 5-24).
Fig. 5-11 Network configuration:
Point-to-point with fiber optic section, 2-wire half-duplex (RS485 interface)
LTOP1
LTOP1
LTOP1
overvoltage
protection
6NH9821-0BC11
2-wire
dedicated line
DTE
TIM3V/4
MD2
RS485
MD2
RS485
Cable
6NH7700-2AR60
Cable
6NH7700-2AR60
LTOP1
overvoltage
protection
6NH9821-0BC11
FOm FOm
DTE
TIM3V/4
RS485
fiber optic
section
Terminal pointTerminal point
FOm: fiber
optic module

Table of Contents

Other manuals for Siemens SINAUT ST7