G04 dwell time: always [s] or [ms]
1:
If G95 is active, in spindle revolutions
Bit3: 0:
Errors in ISO mode lead to an alarm
1:
Errors in ISO mode are not output, the block is translated in Siemens mode.
Bit4: 0:
G00 is traversed with the current exact stop - continuous-path mode G code
1:
G00 is always traversed with G09
Bit5: 0:
Modulo rotary axis is positioned at the shortest possible distance
1:
Direction of rotation of modulo rotary axis depends on sign
Bit6: 0:
Only 4-digit program number allowed.
1:
8-digit program number allowed. If the program number has less than 4 digits, it is
expanded to 4 digits with 0.
Bit7: 0:
Axis programming for geometry axis exchange/parallel axes is compatible with ISO mode.
1:
Axis programming for geometry axis exchange/parallel axes in ISO mode is compatible
with Siemens mode.
Bit8: 0:
With cycles, the F value transferred is always interpreted as a feedrate.
1:
With threading cycles, the F value transferred is interpreted as a pitch.
Bit9: 0:
Multiplication with 0.01mm / 0.0001inch is carried out in ISO mode T for G84, G88 and
in standard mode F for G95.
1:
Multiplication with 0.001mm / 0.00001inch is carried out in ISO mode T for G84, G88
and in standard mode F for G95.
Bit10: 0:
With M96 Pxx, the program programmed with Pxx is always called in the case of an
interrupt
1:
With M96 Pxx, CYCLE396.spf is always called in the case of an interrupt
Bit11: 0:
With G54 Pxx, only G54.1 is displayed
1:
With G54 Pxx, the programmed program is displayed after the point, e.g. G54.48
Bit12: 0:
When the subroutine defined with M96 Pxx is called, $P_ISO_STACK is not modified
1:
When the subroutine defined with M96 Pxx is called, $P_ISO_STACK is incremented
Bit13: 0:
G10 is executed without internal STOPRE
Machine data
3.3 Channel-specific machine data
Parameter Manual