4 = Output in accordance with the predefined output specification
Notice:
An auxiliary function output specification configured by MD22035
$MC_AUXFU_ASSIGN_SPEC[ auxIndex ] has a higher priority.
22254 AUXFU_ASSOC_M0_VALUE C01, C03, C10 H2, K1
- Additional M function to stop a program DWORD PowerOn
-
- - -1, -1, -1, -1, -1, -1, -1,
-1...
- - 2/2 M
Description: This machine data defines an additional, predefined M function, which behaves in the
same way as M0. The value of the machine data corresponds to the number of the
auxiliary M function.
Predefined M numbers, such as M0, M1, M2, M3, etc., are not allowed.
Restriction:
See MD10715 $MN_M_NO_FCT_CYCLE
Related to:
MD10714 $MN_M_NO_FCT_EOP,
MD10715 $MN_M_NO_FCT_CYCLE,
MD20094 $MC_SPIND_RIGID_TAPPING_M_NR,
MD22254 $MC_AUXFU_ASSOC_M0_VALUE
MD10814 $MN_EXTERN_M_NO_MAC_CYCLE,
MD20095 $MC_EXTERN_RIGID_TAPPING_M_NR
22256 AUXFU_ASSOC_M1_VALUE C01, C03, C10 H2
- Additional M function for conditional stop DWORD PowerOn
-
- - -1, -1, -1, -1, -1, -1, -1,
-1...
- - 2/2 M
Description: This machine data defines an additional, predefined M function, which behaves in the
same way as M1. The value of the machine data corresponds to the number of the
auxiliary M function.
Predefined M numbers, such as M0, M1, M2, M3, etc., are not allowed.
Restriction:
See MD10715 $MN_M_NO_FCT_CYCLE
Related to:
MD10714 $MN_M_NO_FCT_EOP,
MD10715 $MN_M_NO_FCT_CYCLE,
MD20094 $MC_SPIND_RIGID_TAPPING_M_NR,
MD22254 $MC_AUXFU_ASSOC_M0_VALUE
MD10814 $MN_EXTERN_M_NO_MAC_CYCLE,
MD20095 $MC_EXTERN_RIGID_TAPPING_M_NR
22400 S_VALUES_ACTIVE_AFTER_RESET C04, C03, C05 -
- S function active beyond RESET BOOLEAN PowerOn
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 2/2 M
Description: 1: The last S values set in the main run are still active after a RESET.
Machine data
3.3 Channel-specific machine data
Parameter Manual
182 List Manual, 01/2017