This also applies to the dynamic correction values ACC, VELOLIM in spindle mode.
0: The various S values are equal to 0 after a RESET, and must therefore be
reprogrammed.
The dynamic correction values ACC and VELOLIM are reset to 100% for spindle mode if
the axis-specific MD35040 $MA_SPIND_ACTIVE_AFTER_RESET and MD32320
$MA_DYN_LIMIT_RESET_MASK do not specify anything else.
Note:
The values for ACC and VELOLIM are also retained for spindle mode if MD35040
$MA_SPIND_ACTIVE_AFTER_RESET is not equal to zero or the axis-specific MD35040
$MA_SPIND_ACTIVE_AFTER_RESET is not equal to zero.
22410 F_VALUES_ACTIVE_AFTER_RESET C04, C03, C05 M3, V1
- F function active beyond RESET BOOLEAN PowerOn
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 2/2 M
Description: 1: The last programmed F, FA, OVR and OVRA values are still active after RESET.
This also applies to the dynamic correction values (ACC, VELOLIM, JERKLIM, ACCLIMA,
VELOLIMA, JERKLIMA).
0: The various values are set to their default values after reset.
This does not apply to the dynamic correction values if the axis-specific MD32320
$MA_DYN_LIMIT_RESET_MASK specifies anything else.
Note:
The dynamic correction values are also retained if the axis-specific MD32320
$MA_DYN_LIMIT_RESET_MASK is not equal to zero.
Related to:
22510 GCODE_GROUPS_TO_PLC C04 K1, P3 pl, P3 sl
- G codes output at NCK-PLC interface on block change/RESET BYTE PowerOn
-
- 8 2, 0, 0, 0, 0, 0, 0, 0 - - 1/1 M
Description: Specification of the G code group, the G codes of which are output to the NCK/PLC
interface in case of block change/ reset.
The interface is updated after each block change and reset.
Notice:
It is not guaranteed that a PLC user program has at all times a block-synchronous
relation between the active NC block and the G codes present.
Example: Path mode with very short blocks
22512 EXTERN_GCODE_GROUPS_TO_PLC C11, C04 -
- Send G codes of an external NC language to PLC BYTE PowerOn
-
- 8 18, 0, 0, 0, 0, 0, 0, 0 - - 1/1 M
Description: Specification of the G code group of external languages, the G codes of which are
output at the NCK interface on block change/reset.
The interface is updated at each block change and after RESET.
Notice:
It is not guaranteed that a PLC user program has at all times a block-synchronous
relation
between the active NC block and the G codes present. (Example: Path mode with
very short blocks).
Machine data
3.3 Channel-specific machine data
Parameter Manual
List Manual, 01/2017 183