EasyManua.ls Logo

Siemens SINUMERIK 810D - Page 744

Siemens SINUMERIK 810D
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview of Alarms 11/2006
SIMODRIVE alarms
2-744
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
300759 Axis %1 drive %2 generator mode: response voltage > monitoring
threshold
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The value in MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) is
greater than MD1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for DC link
monitoring).
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: Please inform the authorized personnel/service department.
Modify drive machine data
- Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or
- Modify MD 1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for DC link
monitoring).
Program
Continuation:
Clear alarm with the RESET key in all channels. Restart part program.
300760 Axis %1 drive %2 generator mode: emergency retraction speed > max.
motor speed
Parameters: %1 = NC axis number
%2 = Drive number
Definitions: The value entered for the emergency retraction speed in MD1639: $MD_RETRACT_SPEED
(emergency retraction speed) is greater than MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED
(maximum motor speed).
Reaction: NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: Please inform the authorized personnel/service department.
Modify drive machine data
- Modify MD 1639: $MD_RETRACT_SPEED (emergency retraction speed) or
- Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
Program
Continuation:
Clear alarm with the RESET key in all channels. Restart part program.