04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–151
SINUMERIK 840C / SIMODRIVE 611–D (DA)
160043 Illegal measurement/meas. value combination OK softkey
Parameterization/starting measuring functions
The measuring function cannot be started
The selected measurement is not accessible with the selected signal
Correct signal selection or measurement selection
160044 Travel function cannot be started OK softkey
When starting startup traversing movements
Function cannot be started
Traversing function not possible because of an alarm, missing controller or feedrate enable
Check enables, acknowledge alarms and repeat procedure
160045 Wrong axis/drive/channel number OK softkey
Startup application
Startup application cannot be started
Selected axis/drive number does not exist
Select available axis/drive number
160046 Axis/spindle has an analog drive OK softkey
When starting startup function
Startup function is not started
A startup function which is not available for analog drives has been selected
Select a different startup function
160047 Axis/spindle has an FDD drive OK softkey
Softkey parameter FDD
FDD parameters are not displayed
No FDD parameters exist for MSD drive
None
160048 Axis/spindle has an FDD drive OK softkey
Softkey parameter MSD
MSD parameters are not displayed
No MSD parameters exist for FDD drive
None
160049 Compare error OK softkey
Startup application
Function aborted
Error on internal consistency check
End application and restart
160050 Data not available OK softkey
Startup application
Function aborted
Error on internal data access
End application and restart
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
1 Alarms
1.5.1 Alarm description