04/96
Siemens AG 2001 All rights reserved 6FC5198–jAB40
1–154
SINUMERIK 840C / SIMODRIVE 611–D (DA)
160067 Timeout OK softkey
Startup application
Startup function is not executed
Timeout error on internal communication
End application and restart
160068 Illegal amplitude OK softkey
Function generator or measuring function parameterization
Function cannot be started
The defined amplitude is illegal
Enter sensible amplitude value
160069 Illegal amplitude 1 OK softkey
Function generator parameterization (square wave)
The function cannot be started
The stated amplitude is illegal
Enter sensible amplitude value
160070 Illegal amplitude 2 OK softkey
Function generator parameterization (staircase)
Function cannot be started
The stated amplitude is illegal
Enter sensible amplitude value
160071 Illegal bandwidth OK softkey
Function generator/measuring function parameterization
Function cannot be started
The bandwidth must be <= of half the sampling rate
Set permissible bandwidth
160072 Illegal scaling OK softkey
Function generator/measuring function parameterization
The function cannot be started
–
Set permissible scaling
160073 Illegal period duration OK softkey
Function generator/measuring function parameterization
The function cannot be started
–
Enter a sensible value not equal to zero
160074 Illegal limitation OK softkey
Function generator/measuring function parameterization
The function cannot be started
–
Enter a lower value not equal to zero
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
Scan
Effect
Explanation
Remedy
1 Alarms