08/2005 Overview of Alarms
2-45
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Configure an M function in the machine data $MN_M_NO_FCT_CYCLE[n] that is not
assigned by the system, or configure a permissible array index in the machine data
$MN_M_NO_FCT_CYCLE_PAR.
Program Con-
tinuation:
Switch control OFF - ON.
4152 Illegal configuration of the 'Block display with absolute values' function
Definitions: The "Block display with absolute values" function has been illegally parameterized:
An illegal block length has been set with $MC_MM_ABSBLOCK:
While ramping up, the machine data will be checked for the following value range: 0, 1,
128 to 512
An invalid display range has been set with $MC_MM_ABSBLOCK_BUFFER_CONF[].
While ramping up, the machine data will be checked for the following upper and lower lim-
its:
0 <= $MC_MM_ABSBLOCK_BUFFER_CONF[0] <= 8
0 <= $MC_MM_ABSBLOCK_BUFFER_CONF[1] <= ($MC_MM_IPO_BUFFER_SIZE +
$MC_MM_NUM_BLOCKS_IN_PREP). Alarm 4152 is issued if the limits are violated.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Configure block length/display range within the permissible limits.
Program Con-
tinuation:
Switch control OFF - ON.
4160 Channel %1 invalid M function number configured for spindle switchover
Parameters: %1 = Channel number
Definitions: An M function was specified in machine data $MC_SPIND_RIGID_TAPPING_M_NR in
order to configure the M function number for spindle switchover. The M function number is
assigned by the system and cannot be used for the switchover (M1 to M5, M17, M30,
M40 to M45).
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: (M1 to M5, M17, M30, M40 to M45). Configure an M function which is not used by the sys-
tem (M1 to M5, M17, M30, M40 to M45) in machine data
$MC_SPIND_RIGID_TAPPING_M_NR.
Program Con-
tinuation:
Switch control OFF - ON.
4170 Invalid M function number for channel synchronisation assigned
Definitions: An M number between 0 and 99 has been specified In machine data
$MN_EXTERN_CHAN_SYNC_M_NR_MIN or
$MN_EXTERN_CHAN_SYNC_M_NR_MAX for the configuration of the M number range

Other manuals for Siemens SINUMERIK 840D sl