01/2007
5.2 First power–up
5-109
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
5.2 First power–up
5.2.1 Basic commissioning of the system software
After the basic commissioning described in the following two sections, the fol-
lowing conditions should apply:
S SINUMERIK 840Di sl NC and PLC are operated in cyclical operation
S If a machine control panel is connected, no alarms or messages should be
pending.
S The displayed axes of the NC can be traversed by simulation.
The hard disk of the PCU is already partitioned upon delivery for operating the
SINUMERIK 840Di sl. Additional software applications which have been been
ordered, e.g. HMI Advanced, are ready for installation under:
S D:\Setup\Apps\<Application1> . . . <Application n>
C:
Name: EMERGENCY
Content: WinPE 2005
D:
Name: TMP
Content: Images,
Setups,
Updates
E:
NTFS
Name: SYSTEM
Content: Windows XP
F:
NTFS
Name: USER
Content: 840Di sl
Primary partition Extended partition with logic drives
NTFS NTFS
Fig. 5-1 Partitioning the hard disk
When the PCU is first booted, the following menu is displayed:
Welcome to SINUMERIK !
These SINUMERIK products will be installed now:
<Application 1> <Version>
<Application n> <Version>
: :
Install NOW
CANCEL installation
Install on NEXT REBOOT
: :
Menu commands:
S Install NOW
All the applications displayed will be installed in the listed order. During the
installation procedure follow the instructions that appear on the screen.
Objective of basic
commissioning
Factory settings
Installing the
software
5 Power On and Power–U