-- Start 840Di start--up: Windows XP taskbar: Start > Programs >
SINUMERIK 840Di > 840Di Start--up
-- Open the dialog box: Menu command Window > Diagnosis > NC/PLC.
S HMI Advanced (option).
-- Open the dialog box: Operating area switchover > Commissioning >
NC/PLC Diagnosis
S Request general reset of PLC: ”PLC Delete Program”.
After general reset the PLC is in RUN mode, i.e. the LED in the display is lit:
”RUN” green.
6.2.6 First co mmissioning
On first commissioning of the PLC, a general reset of the PLC has to be per-
formed after the SINUMERIK 840Di sl has been switched on and booted.
To obtain a defined initial state of the whole system (NC and PLC), the NC data
should also be deleted.
-- PLC general reset
General reset puts the PLC in a defined initial state by deleting and ini-
tializing all system and user data.
-- Delete NC data
After a request to delete NC data, all user data are deleted and the
system data are reinitialized on the next NC power--up, e.g. after NC
Reset.
General reset of the PLC and deletion of NC data can be performed using
840Di Start--up or HMI Advanced.
S 840Di start--up
-- Start: WINDOWS XP taskbar: Start > Programs > SINUMERIK 840Di >
840Di Start--up
-- Open the dialog box: Menu command Window > Diagnosis > NC/PLC
S HMI Advanced
-- Open the dialog box: Operating area switchover > Commissioning >
NC/PLC Diagnosis
Proceed as follows in the dialog boxes:
1. PLC general reset
PLC group
Button: ”PLC Delete Program”
PLC general reset,
deleting NC data
Dialog box
6PLCComm
on
n