8.2 Requirements
8-181
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
The 840Di sl Rack is part of the PLC Toolbox. When the PLC Toolbox is
installed, it is automatically installed in SIMATIC STEP 7.
Note
The PLC basic program must be installed on the computer on which SIMATIC
STEP 7 is installed. For installing the PLC basic program, please observe the
appropriate notes in the file:
S <Installation path>\importantinfo.rtf
Once the PLC basic program has been successfully installed the 840Di sl Rack
can be accessed in the hardware catalog of SIMATIC STEP 7, ”HW Config”:
S ”HW Config” hardware catalog:
Profile: Standard
SIMATIC 300 > SINUMERIK > 840Di sl > 840Di sl
The SlaveOM (Slave
Object Manager) for SINUMERIK 840Di sl permits dialog–
based S7 configuration of the following PROFIBUS drives:
SIMATIC S120
SIMODRIVE 611 universal or universal E
SIMODRIVE POSMO CD/CA
SIMODRIVE POSMO SI distributed servo drive
SIMODRIVE POSMO A
ADI4 (Analog Drive Interface for 4 Axes)
Notice
If the SlaveOM is used in conjunction with other PLC CPUs, a consistency error
is signaled when compiling the S7 configuration and no system data blocks are
generated.
The SlaveOM is part of the PLC Toolbox. When the PLC Toolbox is installed, it
is automatically installed in SIMATIC STEP 7. The DP slave drives specified
above are available in the hardware catalog at the following location:
S HW Config: Hardware catalog:
Profile: Default
PROFIBUS DP > SINAMICS > SINAMICS S120
PROFIBUS DP > SIMODRIVE > SIMODRIVE 611 universal
SIMODRIVE POSMO CD
SIMODRIVE POSMO CA
SIMODRIVE POSMO SI
SIMODRIVE POSMO A
PROFIBUS DP > SINUMERIK > ADI4
Installation
SlaveOM
Installation
8 PROFIBUS DP Communication

Table of Contents