01/2007
8.6 DP slave: MCP 310
8-198
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
The PROFIBUS address and connection type are set with switch S3 on the rear
of the MCP:
Table 8-1 Switch S3: PROFIBUS address (1 – 7)
10
9 8 7 6 5 4 3 2 1 Meaning/value
on on – – – – – – – – Connection type: PROFIBUS
– – off – – – – – – – Reserved
PROFIBUS address
– – – off off off off off off off 0
– – – off off off off off off on 1
– – – on off off off off on off 2
– – – off off off off off on on 3
– – – : : : : : : : :
– – – on on on on on on off 126
– – – on on on on on on on 127
Switch settings 10 – 8 must be set according to the data in the table.
Notice
In the state as delivered, the connection type is: MPI (10 – 9: off, off).
8.6.3 Functions of the machine control panel
The machine control panel offers the following functions:
S Default
S Hand wheel
S Additional I/Os
The function transfers input/output data from the function keys and user–spe-
cific keys and outputs:
S Input data: 8 byte
S Output data: 8 byte
The input/output data for machine control panel MCP 310 is compatible with the
input/output data from the previous machine control panel OP 032S.
The function transfers the absolute values for the two handwheels that can be
connected to the machine control panel:
S Input data: 2 x 2 bytes
Absolute value handwheel 1
Low byte
High byte
Absolute value handwheel 2
For each handwheel the current handwheel value is transferred as a 16–bit ab-
solute value relative to the starting value. The starting value for the sensor
counter in the handwheel is 0.
The absolute values are transferred in big endian format.
Switch S3
Default
Hand wheel
8 PROFIBUS DP Communication